Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 344
Filtrar
1.
IEEE Trans Med Imaging ; 42(4): 1009-1020, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36383595

RESUMO

Optical Coherence Tomography Angiography (OCTA), a functional extension of OCT, has the potential to replace most invasive fluorescein angiography (FA) exams in ophthalmology. So far, OCTA's field of view is however still lacking behind fluorescence fundus photography techniques. This is problematic, because many retinal diseases manifest at an early stage by changes of the peripheral retinal capillary network. It is therefore desirable to expand OCTA's field of view to match that of ultra-widefield fundus cameras. We present a custom developed clinical high-speed swept-source OCT (SS-OCT) system operating at an acquisition rate 8-16 times faster than today's state-of-the-art commercially available OCTA devices. Its speed allows us to capture ultra-wide fields of view of up to 90 degrees with an unprecedented sampling density and hence extraordinary resolution by merging two single shot scans with 60 degrees in diameter. To further enhance the visual appearance of the angiograms, we developed for the first time a three-dimensional deep learning based algorithm for denoising volumetric OCTA data sets. We showcase its imaging performance and clinical usability by presenting images of patients suffering from diabetic retinopathy.


Assuntos
Angiografia , Oftalmologia , Doenças Retinianas , Tomografia de Coerência Óptica , Humanos , Retinopatia Diabética/diagnóstico por imagem , Angiofluoresceinografia/normas , Doenças Retinianas/diagnóstico por imagem , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica/normas , Angiografia/instrumentação , Angiografia/métodos , Angiografia/normas , Oftalmologia/instrumentação , Oftalmologia/métodos
2.
Sci Rep ; 11(1): 23832, 2021 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-34903817

RESUMO

This is a prospective observational study to establish the short- and long-term repeatability of measurements of peripapillary optical coherence tomography angiography (OCTA) parameters in healthy eyes and identify factors affecting long-term repeatability. We enrolled 84 healthy eyes. Participants with a history of any ophthalmic disease (except high myopia) or intraocular surgery were excluded from the study. An experienced examiner performed OCTA using disc-centered 6 × 6 mm scans. All examinations were conducted twice at 5-min intervals at the initial visit and repeated at least 6 months later. For short-term repeatability, the coefficient of variation (CV) was 2.94-4.22% and the intraclass correlation coefficient (ICC) was 0.840-0.934. For long-term repeatability, the CV was 2.73-3.84% and the ICC was 0.737-0.934. Multivariate analyses showed that the axial length (AL) (B = 0.970; p = 0.002) and mean signal strength (SS) (B = - 2.028; p < 0.001) significantly affected long-term repeatability. Measurements of peripapillary OCTA parameters exhibited excellent short-term and good long-term repeatability in healthy individuals. The mean SS and AL affected long-term repeatability and should be considered while interpreting peripapillary OCTA images.


Assuntos
Angiografia/métodos , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Adulto , Idoso , Angiografia/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica/normas
3.
Front Endocrinol (Lausanne) ; 12: 777552, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34956088

RESUMO

Diabetic retinopathy, the most serious ocular complication of diabetes, imposes a serious economic burden on society. Automatic and objective assessment of vessel changes can effectively manage diabetic retinopathy and prevent blindness. Optical coherence tomography angiography (OCTA) metrics have been confirmed to be used to assess vessel changes. The accuracy and reliability of OCTA metrics are restricted by vessel segmentation methods. In this study, a multi-branch retinal vessel segmentation method is proposed, which is comparable to the segmentation results obtained from the manual segmentation, effectively extracting vessels in low contrast areas and improving the integrity of the extracted vessels. OCTA metrics based on the proposed segmentation method were validated to be reliable for further analysis of the relationship between OCTA metrics and diabetes and the severity of diabetic retinopathy. Changes in vessel morphology are influenced by systemic risk factors. However, there is a lack of analysis of the relationship between OCTA metrics and systemic risk factors. We conducted a cross-sectional study that included 362 eyes of 221 diabetic patients and 1,151 eyes of 587 healthy people. Eight systemic risk factors were confirmed to be closely related to diabetes. After controlling these systemic risk factors, significant OCTA metrics (such as vessel complexity index, vessel diameter index, and mean thickness of retinal nerve fiber layer centered in the macular) were found to be related to diabetic retinopathy and severe diabetic retinopathy. This study provides evidence to support the potential value of OCTA metrics as biomarkers of diabetic retinopathy.


Assuntos
Retinopatia Diabética/diagnóstico , Vasos Retinianos/patologia , Tomografia de Coerência Óptica , Idoso , Angiografia/métodos , Angiografia/normas , Contagem de Células/normas , China , Estudos Transversais , Retinopatia Diabética/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Gravidade do Paciente , Valores de Referência , Retina/diagnóstico por imagem , Retina/patologia , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/normas
4.
Eur J Med Res ; 26(1): 123, 2021 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-34649598

RESUMO

Trauma accounts for a third of the deaths in Western countries, exceeded only by cardiovascular disease and cancer. The high risk of massive bleeding, which depends not only on the type of fractures, but also on the severity of any associated parenchymal injuries, makes pelvic fractures one of the most life-threatening skeletal injuries, with a high mortality rate. Therefore, pelvic trauma represents an important condition to correctly and early recognize, manage, and treat. For this reason, a multidisciplinary approach involving trauma surgeons, orthopedic surgeons, emergency room physicians and interventional radiologists is needed to promptly manage the resuscitation of pelvic trauma patients and ensure the best outcomes, both in terms of time and costs. Over the years, the role of interventional radiology in the management of patient bleeding due to pelvic trauma has been increasing. However, the current guidelines on the management of these patients do not adequately reflect or address the varied nature of injuries faced by the interventional radiologist. In fact, in the therapeutic algorithm of these patients, after the word "ANGIO", there are no reports on the different possibilities that an interventional radiologist has to face during the procedure. Furthermore, variations exist in the techniques and materials for performing angioembolization in bleeding patients with pelvic trauma. Due to these differences, the outcomes differ among different published series. This article has the aim to review the recent literature on optimal imaging assessment and management of pelvic trauma, defining the role of the interventional radiologist within the multidisciplinary team, suggesting the introduction of common and unequivocal terminology in every step of the angiographic procedure. Moreover, according to these suggestions, the present paper tries to expand the previously drafted algorithm exploring the role of the interventional radiologist in pelvic trauma, especially given the multidisciplinary setting.


Assuntos
Angiografia/normas , Fraturas Ósseas/diagnóstico por imagem , Hemorragia/diagnóstico por imagem , Ossos Pélvicos/lesões , Centros de Traumatologia/normas , Ferimentos e Lesões/complicações , Fraturas Ósseas/etiologia , Fraturas Ósseas/patologia , Hemorragia/etiologia , Hemorragia/patologia , Humanos
5.
Ann Surg ; 274(6): e659-e663, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34145192

RESUMO

OBJECTIVE: This study aims to generate a reproducible and generalizable Workflow model of ICG-angiography integrating Standardization and Quantification (WISQ) that can be applied uniformly within the surgical innovation realm independent of the user. SUMMARY BACKGROUND DATA: Tissue perfusion based on indocyanine green (ICG)-angiography is a rapidly growing application in surgical innovation. Interpretation of results has been subjective and error-prone due to the lack of a standardized and quantitative ICG-workflow and analytical methodology. There is a clinical need for a more generic, reproducible, and quantitative ICG perfusion model for objective assessment of tissue perfusion. METHODS: In this multicenter, proof-of-concept study, we present a generic and reproducible ICG-workflow integrating standardization and quantification for perfusion assessment. To evaluate our model's clinical feasibility and reproducibility, we assessed the viability of parathyroid glands after performing thyroidectomy. Biochemical hypoparathyroidism was used as the postoperative endpoint and its correlation with ICG quantification intraoperatively. Parathyroid gland is an ideal model as parathyroid function post-surgery is only affected by perfusion. RESULTS: We show that visual subjective interpretation of ICG-angiography by experienced surgeons on parathyroid perfusion cannot reliably predict organ function impairment postoperatively, emphasizing the importance of an ICG quantification model. WISQ was able to standardize and quantify ICG-angiography and provided a robust and reproducible perfusion curve analysis. A low ingress slope of the perfusion curve combined with a compromised egress slope was indicative for parathyroid organ dysfunction in 100% of the cases. CONCLUSION: WISQ needs prospective validation in larger series and may eventually support clinical decision-making to predict and prevent postoperative organ function impairment in a large and varied surgical population.


Assuntos
Angiografia/normas , Verde de Indocianina , Glândulas Paratireoides/irrigação sanguínea , Glândulas Paratireoides/diagnóstico por imagem , Tireoidectomia/normas , Fluxo de Trabalho , Estudos de Viabilidade , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/prevenção & controle , Estudo de Prova de Conceito , Estudos Prospectivos , Reprodutibilidade dos Testes
6.
PLoS One ; 16(2): e0246469, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33571215

RESUMO

PURPOSE: OCT-angiography (OCT-A) offers a non-invasive method to visualize retinochoroidal microvasculature. As glaucoma disease affects retinal ganglion cells in the macula, macular microcirculation is of interest. The purpose of the study was to investigate regional macular vascular characteristics in patients with ocular hypertension (OHT), pre-perimetric primary open-angle glaucoma (pre-POAG) and controls by OCT-A in three microvascular layers. MATERIAL AND METHODS: 180 subjects were recruited from the Erlangen Glaucoma Registry, the Department of Ophthalmology, University of Erlangen and residents: 38 OHT, 20 pre-POAG, 122 controls. All subjects received an ophthalmological examination including measurements of retinal nerve fibre layer (RNFL), retinal ganglion cell layer (RGC), inner nuclear layer (INL), and Bruch's Membrane Opening-Minimum Rim Width (BMO-MRW). Macular vascular characteristics (vessel density, VD, foveal avascular zone, FAZ) were measured by OCT-A (Spectralis OCT II) in superficial vascular plexus (SVP), intermediate capillary plexus (ICP), and deep capillary plexus (DCP). RESULTS: With age correction of VD data, type 3 tests on fixed effects showed a significant interaction between diagnosis and sectorial VD in SVP (p = 0.0004), ICP (p = 0.0073), and DCP (p = 0.0003). Moreover, a significance in sectorial VD was observed within each layer (p<0.0001) and for the covariate age (p<0.0001). FAZ differed significantly between patients' groups only in ICP (p = 0.03), not in SVP and DCP. For VD the AUC values of SVP, ICP, and DCP were highest among diagnostic modalities (AUC: 0.88, 95%-CI: 0.75-1.0, p<0.001). CONCLUSION: Regional reduced macula VD was observed in all three retinal vascular layers of eyes with OHT and pre-POAG compared to controls, indicating localized microvascular changes as early marker in glaucoma pathogenesis.


Assuntos
Angiografia/métodos , Glaucoma de Ângulo Aberto/diagnóstico por imagem , Macula Lutea/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Idoso , Idoso de 80 Anos ou mais , Angiografia/normas , Feminino , Humanos , Macula Lutea/irrigação sanguínea , Macula Lutea/inervação , Masculino , Pessoa de Meia-Idade , Nervo Óptico/diagnóstico por imagem , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica/normas
7.
J Vasc Surg ; 73(1): 151-160.e2, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32623109

RESUMO

BACKGROUND: The use of intraoperative completion imaging (completion carotid duplex ultrasound or angiography) to confirm the technical adequacy of carotid endarterectomy (CEA) remains a matter of controversy. The purpose of this study was to describe vascular surgeons' practice patterns in the use of completion imaging after CEA and to study the association between completion imaging and postoperative stroke/death and high-grade restenosis (>70%). METHODS: Patients who underwent CEA without concomitant procedures in the Vascular Quality Initiative database between 2003 and 2018 were included. Surgeons' practice patterns were defined on the basis of the distribution of completion imaging use among annual CEA cases per surgeon. Multivariable and Cox proportional hazards models were used to study the association between different practice patterns of completion imaging and perioperative and 1-year outcomes after CEA. RESULTS: Of 98,055 CEA cases, 26,716 (27.3%) were performed with completion imaging. Compared with cases in which completion imaging was not performed, completion imaging was associated with increased rates of immediate re-exploration (3.5% vs 0.9%; odds ratio [OR], 3.84; 95% confidence interval [CI], 2.74-5.38; P < .001), overall return to the operating room (RTOR; 1.6% vs 1.2%; OR, 1.24; 95% CI, 1.08-1.42; P < .01), and longer operative time (median [interquartile range], 105 minutes [82-132] vs 119 minutes [92-148]; P < .001). Of 1920 surgeons in our cohort, 45% never performed completion imaging, whereas 26% rarely performed completion imaging (for ≤20% of annual CEA cases), 9.5% performed it selectively (21%-79% of annual CEAs), and 19.6% used completion imaging routinely (≥80% of annual CEAs). Rarely performing completion imaging had higher rates of immediate re-exploration (6.5% vs 0.9%; OR, 7.2; 95% CI, 5.7-9.2; P < .001), in-hospital stroke (4.0% vs 1.1%; adjusted OR [aOR], 3.4; 95% CI, 2.6-4.6; P < .001), RTOR for bleeding (1.9% vs 0.9%; aOR, 2.1; 95% CI, 1.5-2.9; P < .001), and neurologic events (1.5% vs 0.4%; aOR, 3.6; 95% CI, 2.2-5.9; P < .001) compared with not performing completion imaging. It was also associated with increased stroke/death and repeated revascularization at 30 days and significant restenosis at 1 year. On the other hand, performance of selective and routine completion imaging was associated with increased immediate re-exploration (selective: aOR, 3.2 [95% CI, 1.9-5.5; P < .001]; routine: aOR, 3.7 [95% CI, 2.5-5.6; P < .001]) without any increase in in-hospital, 30-day, and 1-year adverse outcomes compared with cases performed without completion imaging. CONCLUSIONS: The performance of selective or routine completion imaging during CEA is safe and is not associated with increased adverse events compared with not using intraoperative completion imaging. However, rarely performing completion imaging is associated with a significant increase in the odds of perioperative stroke/death and RTOR, possibly because of unnecessary re-exploration for minor defects. The operator's experience and establishing a criterion for fixing residual defects are important to avoid unnecessary re-exploration.


Assuntos
Estenose das Carótidas/cirurgia , Diagnóstico por Imagem/normas , Endarterectomia das Carótidas , Complicações Pós-Operatórias/diagnóstico , Padrões de Prática Médica , Sistema de Registros , Cirurgiões/normas , Idoso , Angiografia/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Ultrassonografia Doppler Dupla/normas
8.
PLoS One ; 15(6): e0234664, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32544179

RESUMO

PURPOSE: To compare quantitative changes in macular parameters in diabetic patients detected by two optical coherence tomography angiography (OCTA) instruments. METHODS: 80 phakic eyes were classified as no diabetes, diabetes without diabetic retinopathy (DR), mild non-proliferative diabetic retinopathy (NPDR), and severe NPDR or proliferative DR (PDR). OCTA was performed using devices from two manufacturers (Zeiss and Heidelberg). Superficial and deeper vascular skeleton density (SVSD, DVSD), superficial and deeper vessel area density (SVAD, DVAD), choriocapillaris flow voids (CCFV), and choroidal flow voids (CFV) were calculated. Inter-device comparisons were performed using the size comparison index (SCI) and the discrepancy index (DI). RESULTS: The two devices were inconsistent in SVSD, DVSD, DVAD, CCFV and CFV parameters (all P < 0.05). In addition, the SCI was positive for DVAD (all P < 0.001) and negative for SVSD, DVSD, CCFV and CFV in all groups (all P <0.001), except for DVSD in severe NPDR or PDR. The discrepancy index was not significantly different among groups for SVD, SPD, DVD, DPD and CFV (all P> 0.05). The mean DI of CCFV was statistically different between the four groups (P < 0.001). CONCLUSIONS: The two instruments were largely inconsistent in the measurement of macular parameters relevant to DR. The choice of imaging device can impact OCTA analytics and should be taken into account when drawing conclusions about DR-related changes.


Assuntos
Angiografia , Diabetes Mellitus/fisiopatologia , Retinopatia Diabética/diagnóstico por imagem , Olho/diagnóstico por imagem , Tomografia de Coerência Óptica/instrumentação , Angiografia/instrumentação , Angiografia/métodos , Angiografia/normas , Estudos de Casos e Controles , Complicações do Diabetes/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/normas
9.
J Surg Res ; 253: 224-231, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32380348

RESUMO

BACKGROUND: Surgical exploration for gunshot wounds to the abdomen has been a surgical standard for the greater part of the past century. Recently, nonoperative management (NOM) has been deemed as a safe option for abdominal gunshot wounds (AGWs). The aim of this analysis was to review the utilization of NOM and mortality after AGWs. METHODS: We performed a 2010-2014 retrospective analysis of the American College of Surgeons Trauma Quality and Improvement Program. We included all adult (aged 18 and older) patients with AGWs. NOM was defined as nonsurgical intervention within the first 6 h. Outcome measures were trends of utilization of NOM and mortality. Cochrane-Armitage trend analysis was performed. RESULTS: A total of 808,272 trauma patients were identified, and 16,866 patients with AGWs were included. During the study period, the incidence of AGWs increased, whereas the proportion of bowel injury (P = 0.75) and solid organ injury (P = 0.44) did not change. The NOM rate of AGW increased (2010: 19.5% versus 2014: 27%, P < 0.001). This was accompanied by a decrease in mortality rate (11% versus 9.4%, P = 0.01). Likewise, there was an increase in the use of angiography (7.5% versus 27%, P < 0.001) and laparoscopy (0.9% versus 2.6%, P < 0.001). Overall, 9.8% of the patients had failed NOM. There was no difference in mortality in patients who were managed successfully or failed NOM (5% versus 4.6%, P = 0.45). CONCLUSIONS: NOM of AGW is more prevalent and is associated with a decrease in mortality rate. Selective NOM may be practiced safely after AGWs.


Assuntos
Traumatismos Abdominais/terapia , Angiografia/tendências , Tratamento Conservador/tendências , Laparoscopia/tendências , Ferimentos por Arma de Fogo/terapia , Traumatismos Abdominais/diagnóstico , Traumatismos Abdominais/mortalidade , Adulto , Angiografia/normas , Angiografia/estatística & dados numéricos , Tratamento Conservador/normas , Tratamento Conservador/estatística & dados numéricos , Feminino , Humanos , Incidência , Escala de Gravidade do Ferimento , Laparoscopia/normas , Laparoscopia/estatística & dados numéricos , Tempo de Internação , Masculino , Seleção de Pacientes , Guias de Prática Clínica como Assunto , Estudos Retrospectivos , Análise de Sobrevida , Falha de Tratamento , Estados Unidos/epidemiologia , Ferimentos por Arma de Fogo/diagnóstico , Ferimentos por Arma de Fogo/mortalidade , Adulto Jovem
10.
PLoS One ; 15(3): e0230260, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32196538

RESUMO

INTRODUCTION: For quantification of Optical Coherence Tomography Angiography (OCTA) images, Vessel Density (VD) and Vessel Skeleton Density (VSD) are well established parameters and different algorithms are in use for their calculation. However, comparability, reliability and ability to discriminate healthy and impaired macular perfusion of different algorithms are unclear, yet, of potential high clinical relevance. Hence, we assessed comparability and test-retest reliability of the most common approaches. MATERIALS AND METHODS: Two consecutive 3×3mm OCTA en face images of the superficial and deep retinal layer were acquired with swept-source OCTA. VD and VSD were calculated with manual thresholding and six automated thresholding algorithms (Huang, Li, Otsu, Moments, Mean, Percentile) using ImageJ and compared in terms of intra-class correlation coefficients, measurement differences and repeatability coefficients. Receiver operating characteristic analyses (healthy vs. macular pathology) were performed and Area Under the Curve (AUC) values were calculated. RESULTS: Twenty-six eyes (8 female, mean age: 47 years) of 15 patients were included (thereof 15 eyes with macular pathology). Binarization thresholds, VD and VSD differed significantly between the algorithms and compared to manual thresholding (p < 0.0001). Inter-measurement differences did not differ significantly between patients with healthy versus pathologic maculae (p ≥ 0.685). Reproducibility was higher for the automated algorithms compared to manual thresholding on all measures of reproducibility assessed. AUC was significantly higher for the Mean algorithm compared to the manual approach with respect to the superficial retinal layer. CONCLUSIONS: Automated thresholding algorithms yield a higher reproducibility of OCTA parameters and allow for a more sensitive diagnosis of macular pathology. However, different algorithms are not interchangeable nor results readily comparable. Especially the Mean algorithm should be investigated in further detail. Automated thresholding algorithms are preferable but more standardization is needed for clinical use.


Assuntos
Angiografia/métodos , Degeneração Macular/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Algoritmos , Angiografia/normas , Automação/métodos , Automação/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica/normas
11.
Sci Rep ; 10(1): 4470, 2020 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-32161286

RESUMO

An increasing number of centers not necessarily equipped with biplane (BP) angiosuites are performing mechanical thrombectomy (MT) in acute ischemic stroke patients. We assessed whether MT performed on single-plane (SP) is equivalent in terms of safety, effectiveness, radiation and contrast agent exposure. Consecutive patients treated by MT in four high volume centers between January 2014 and May 2017 were included. Demographic and MT characteristics were assessed and compared between SP and BP. Of 906 patients treated by MT, 576 (64%) were handled on a BP system. After multivariate analysis, contrast load and fluoroscopy duration were significantly lower in the BP group [100vs200mL, relative effect 0.85 (CI: 0.79-0.92), p = 0.0002; 22 vs 27 min, relative effect 0.84 (CI: 0.76-0.93), p = 0.0008, respectively]. There was no difference in recanalization (modified Thrombolysis-In-Cerebral-Infarction 2b-3), good clinical outcome (modified Rankin Scale 0-2), complications rates, procedure duration or radiation exposure. A three-vessel diagnostic angiogram performed prior to MT led to a significant increase in procedure duration (15% increase, p = 0.05), radiation exposure (33% increase, p < 0.0001) and contrast load (125% increase, p < 0.0001). Mechanical neuro-thrombectomy seems equally safe and effective on a single or biplane angiography system despite increased contrast load and fluoroscopy duration on the former.


Assuntos
Angiografia/métodos , Trombectomia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia/efeitos adversos , Angiografia/normas , Feminino , Humanos , Masculino , Trombólise Mecânica/métodos , Pessoa de Meia-Idade , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/terapia , Trombectomia/efeitos adversos , Trombectomia/normas , Resultado do Tratamento , Adulto Jovem
12.
Catheter Cardiovasc Interv ; 96(1): 145-155, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32061033

RESUMO

Evidence-based recommendations for clinical practice are intended to help health care providers and patients make decisions, minimize inappropriate practice variation, promote effective resource use, improve clinical outcomes, and direct future research. The Society for Cardiovascular Angiography and Interventions (SCAI) has been engaged in the creation and dissemination of clinical guidance documents since the 1990s. These documents are a cornerstone of the society's education, advocacy, and quality improvement initiatives. The publications committee is charged with oversight of SCAI's clinical documents program and has created this manual of standard operating procedures to ensure consistency, methodological rigor, and transparency in the development and endorsement of the society's documents. The manual is intended for use by the publications committee, document writing groups, external collaborators, SCAI representatives, peer reviewers, and anyone seeking information about the SCAI documents program.


Assuntos
Comitês Consultivos/normas , Angiografia/normas , Cateterismo Cardíaco/normas , Procedimentos Endovasculares/normas , Manuais como Assunto/normas , Intervenção Coronária Percutânea/normas , Guias de Prática Clínica como Assunto/normas , Sociedades Médicas/normas , Medicina Baseada em Evidências/normas , Humanos , Redação/normas
14.
Biomed Phys Eng Express ; 6(2): 025008, 2020 02 18.
Artigo em Inglês | MEDLINE | ID: mdl-33438634

RESUMO

The goal of this paper was the comparison of radiation dose and imaging quality before and after the Clarity IQ technology installation in a Philips AlluraXper FD20/20 angiography system using a Channelized Hotelling Observer model (CHO). The core characteristics of the Allura Clarity IQ technology are its real-time noise reduction algorithms (NRT) combined with state-of-the-art hardware; this technology allows to implement acquisition protocols able to significantly reduce patient entrance dose. To measure the system performances in terms of image quality we used a contrast detail phantom in a clinical scatter condition. A Leeds TO10 phantom has been imaged between two 10 cm thick homogeneous solid water slabs. Fluoroscopy images were acquired using a cerebral protocol at 3 dose levels (low, medium and high) with a field- of view (FOV) of 31 cm. Cineangiography images were acquired using a cerebral protocol at 2 fps. Thus, 4 acquisitions were obtained for the conventional technology and 4 acquisitions were taken after the Clarity IQ upgrade, for a total of 8 different image sets. A validated 40 Gabor channels CHO with an internal noise model compared the image sets. Human observers' studies were carried out to tune the internal noise parameter. We showed that the CHO did not detect any significant difference between any of the image sets acquired using the two technologies. Consequently, this x-ray imaging technology provides a non-inferior image quality with an average patient dose reduction of 57% and 28% respectively in cineangiography and fluoroscopy. The Clarity IQ installation has certainly allowed a considerable improvement in patient and staff safety, while maintaining the same image quality.


Assuntos
Algoritmos , Angiografia/normas , Processamento de Imagem Assistida por Computador/normas , Variações Dependentes do Observador , Imagens de Fantasmas , Controle de Qualidade , Tomografia Computadorizada por Raios X/métodos , Cineangiografia/métodos , Fluoroscopia/métodos , Humanos , Doses de Radiação
15.
Vasc Med ; 24(2): 164-189, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30648921

RESUMO

This article is a comprehensive document on the diagnosis and management of fibromuscular dysplasia (FMD), which was commissioned by the working group 'Hypertension and the Kidney' of the European Society of Hypertension (ESH) and the Society for Vascular Medicine (SVM). This document updates previous consensus documents/scientific statements on FMD published in 2014 with full harmonization of the position of European and US experts. In addition to practical consensus-based clinical recommendations, including a consensus protocol for catheter-based angiography and percutaneous angioplasty for renal FMD, the document also includes the first analysis of the European/International FMD Registry and provides updated data from the US Registry for FMD. Finally, it provides insights on ongoing research programs and proposes future research directions for understanding this multifaceted arterial disease.


Assuntos
Angiografia/normas , Angioplastia/normas , Fármacos Cardiovasculares/uso terapêutico , Displasia Fibromuscular/diagnóstico por imagem , Displasia Fibromuscular/terapia , Angioplastia/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Tomada de Decisão Clínica , Consenso , Displasia Fibromuscular/epidemiologia , Predisposição Genética para Doença , Humanos , Valor Preditivo dos Testes , Fatores de Risco , Resultado do Tratamento
16.
Sci Rep ; 8(1): 10143, 2018 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-29973663

RESUMO

This study was conducted to investigate the size and shape of the foveal avascular zone (FAZ) determined by optical coherence tomography angiography (OCTA) and the relationship of the size and shape to the clinical findings in normal subjects. This was a cross-sectional study with seventy eyes of 70 volunteers. The size of the superficial FAZs were assessed by its area, length of perimeter, and Feret's diameter, and the shape by the circularity, axial ratio, roundness, and solidity. The correlations between each parameter and the clinical findings were statistically determined. The coefficients of variation (CV) of the parameters of FAZ size were higher than that of the parameters of FAZ shape. The refractive error and axial length were significantly correlated with area-related factors. The central macular thickness (CMT) was significantly correlated with all parameters. Although the CMT was a critical factor that was significantly correlated with the size and shape characteristics of the FAZ, the shape might be a better factor for characterizing the FAZ than the size because of the low CV of shape-related factors and the characteristics are less affected by the other ocular factors.


Assuntos
Angiografia/métodos , Fóvea Central/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Adulto , Angiografia/normas , Feminino , Fóvea Central/irrigação sanguínea , Humanos , Masculino , Pessoa de Meia-Idade , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica/normas
17.
Contrast Media Mol Imaging ; 2018: 7647165, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29780288

RESUMO

Introduction: Iodinated contrast media completion angiography (ICM-A) may underestimate the presence of type II endoleak (ELII) after endovascular aortic repair (EVAR), particularly if they are at low flow. Contrast-enhanced ultrasound (CEUS) has been proposed as the gold standard in ELII detection during EVAR follow-up. Intraprocedural carbon dioxide (CO2) angiography has been shown to be useful in this setting; however no comparative studies including these three techniques are currently available. Our aim was to investigate the accuracy of a new automated CO2 angiographic (CO2-A) system in the detection of ELII, by comparing it with ICM-A and CEUS. Methods: A series of consecutive patients undergoing EVAR for abdominal aortic aneurysm (AAA) were enrolled and submitted to ICM-A and CO2-A during the procedure. The iodinated contrast media were delivered through an automatic injector connected to a pigtail catheter in the suprarenal aorta. CO2 was delivered through a recently available automatic injector connected to a 10 F sheath positioned in the external iliac artery. All patients were blindly evaluated by CEUS within postoperative day 1. The ICM-A and CO2-A ability to detect ELII was compared with that of CEUS through Cohen's concordance Index (K). Results: Twenty-one patients were enrolled in the study. One (5%), seven (33%), and four (19%) ELII were detected by ICM-A, CO2-A, and CEUS, respectively. The only ELII detected by ICM-A was also detected by CO2-A and CEUS. Three cases of ELII detected by CO2-A were not detected by CEUS. All ELII detected by CEUS were visualized by CO2-A. CEUS and ICM-A showed a poor agreement (Cohen's K: 0.35) while CEUS and CO2-A showed a substantial agreement (Cohen's K: 0.65) for ELII detection. Conclusion: CO2-A is safe and effective method for ELII detection in EVAR, with a significantly higher agreement with CEUS if compared with ICM-A. This trial is registered with 155/2015/U/Oss.


Assuntos
Angiografia/métodos , Endoleak/diagnóstico por imagem , Ultrassonografia/métodos , Idoso , Idoso de 80 Anos ou mais , Angiografia/normas , Aneurisma da Aorta Abdominal/complicações , Dióxido de Carbono , Meios de Contraste , Procedimentos Endovasculares , Humanos , Masculino , Resultado do Tratamento , Ultrassonografia/normas
18.
J Vet Intern Med ; 32(3): 956-961, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29528135

RESUMO

BACKGROUND: Different methods to perform reference calibration of an angiographic image exist; however, a prospective comparison of calibration methods has yet to be investigated in veterinary medicine. OBJECTIVE: To compare angiographic measurements using two commonly employed reference calibration methods, an esophageal pigtail marker catheter (EC) versus a radiopaque table ruler (TR). ANIMALS: Thirty-five client-owned dogs undergoing transcatheter intervention. METHODS: Prospective comparison study. Two reference calibration methods, EC and TR, were recorded in dogs undergoing transcatheter procedures from May 2016 to July 2017. Relevant measurements were performed in triplicate and averaged after image calibration to either EC or TR. Comparisons between methods were made by correlation, paired t-test, the method of Bland and Altman, and Passing-Bablok regression. RESULTS: A total of 39 angiographic structures were measured. Interventions included balloon pulmonary valvuloplasty (n = 21), patent ductus arteriosus occlusion (n = 11), subaortic or sub-pulmonary balloon dilatation (n = 4), and cor triatriatum membranostomy (n = 3). Angiographic measurements were larger when calibrated to EC versus TR (P < .0001). The mean bias was 0.86 mm, with greater bias for larger measurements. The EC measurements were ∼10% greater than TR based on regression analysis. Weight was correlated to the difference between methods (ρ = 0.55, P = .0003). CONCLUSIONS AND CLINICAL IMPORTANCE: Angiographic image calibration using a ruler placed on the fluoroscopy table underestimates the size of a structure by ∼10% as compared with a marker catheter placed within the esophagus. This effect is greatest when measuring larger structures such as the pulmonary valve annulus and in larger dogs.


Assuntos
Angiografia/veterinária , Angiografia/métodos , Angiografia/normas , Animais , Calibragem , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/normas , Cateterismo Cardíaco/veterinária , Doenças do Cão/diagnóstico por imagem , Cães , Fluoroscopia/veterinária , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/veterinária , Estudos Prospectivos , Reprodutibilidade dos Testes
19.
J Am Soc Echocardiogr ; 31(4): 381-404, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29066081

RESUMO

This document is 1 of 2 companion appropriate use criteria (AUC) documents developed by the American College of Cardiology, American Association for Thoracic Surgery, American Heart Association, American Society of Echocardiography, American Society of Nuclear Cardiology, Heart Rhythm Society, Society for Cardiovascular Angiography and Interventions, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, and Society of Thoracic Surgeons. This document addresses the evaluation and use of multimodality imaging in the diagnosis and management of valvular heart disease, whereas the second, companion document addresses this topic with regard to structural heart disease. Although there is clinical overlap, the documents addressing valvular and structural heart disease are published separately, albeit with a common structure. The goal of the companion AUC documents is to provide a comprehensive resource for multimodality imaging in the context of valvular and structural heart disease, encompassing multiple imaging modalities. Using standardized methodology, the clinical scenarios (indications) were developed by a diverse writing group to represent patient presentations encountered in everyday practice and included common applications and anticipated uses. Where appropriate, the scenarios were developed on the basis of the most current American College of Cardiology/American Heart Association guidelines. A separate, independent rating panel scored the 92 clinical scenarios in this document on a scale of 1 to 9. Scores of 7 to 9 indicate that a modality is considered appropriate for the clinical scenario presented. Midrange scores of 4 to 6 indicate that a modality may be appropriate for the clinical scenario, and scores of 1 to 3 indicate that a modality is considered rarely appropriate for the clinical scenario. The primary objective of the AUC is to provide a framework for the assessment of these scenarios by practices that will improve and standardize physician decision making. AUC publications reflect an ongoing effort by the American College of Cardiology to critically and systematically create, review, and categorize clinical situations where diagnostic tests and procedures are utilized by physicians caring for patients with cardiovascular diseases. The process is based on the current understanding of the technical capabilities of the imaging modalities examined.


Assuntos
American Heart Association , Cardiologia , Doenças das Valvas Cardíacas/diagnóstico , Imagem Multimodal/normas , Sociedades Médicas , Cirurgia Torácica , Angiografia/normas , Ecocardiografia/normas , Doenças das Valvas Cardíacas/cirurgia , Humanos , Imagem Cinética por Ressonância Magnética/normas , Tomografia Computadorizada por Raios X/normas , Estados Unidos
20.
Clin Neurol Neurosurg ; 164: 14-18, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29145041

RESUMO

OBJECTIVES: Transradial cerebral angiography (TRCA) has been introduced as an alternative technique for the transfemoral access, and its use is becoming more common in the field. In this study, we retrospectively analyzed a group of patients who received TRCA, and investigated peri-procedural measurements indicating actual hand circulation, and studied their correlation with the Allen test. PATIENTS AND METHODS: A retrospective review of 168 patients whom underwent TRCA between 2015 July and 2016 July, were included in this study. Pre procedural Allen test and Doppler ultrasonography for the radial artery (RA) and ulnar artery (UA) were done. Plethysmography tests as well as pulse oximetry monitoring were done before and during the procedure and intra-procedural angiography of the forearm and hand was done for assessment of palmar circulation. RESULTS: Pre-procedural UA diameters revealed statistically significant correlation with manual Allen test results (P <0.001, r=-0.381). The DUS RA diameters, however, did not correlate with any other pre-procedural measurements. The mean contrast filling time on forearm angiography was 3.33±1.97s, and it showed statistically significant correlation with the capillary filling time of Allen tests (P<0.001, r=0.389). CONCLUSION: Manual Allen test results correlated with angiographic capillary filling of the distal hand circulation and pre-procedural UA diameters. Our results suggest that Allen test sufficiently represent the collateral circulation status prior to TRCA.


Assuntos
Angiografia Cerebral/métodos , Angiografia Cerebral/normas , Circulação Cerebrovascular/fisiologia , Circulação Colateral/fisiologia , Mãos/irrigação sanguínea , Mãos/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia/métodos , Angiografia/normas , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fluxo Sanguíneo Regional/fisiologia , Estudos Retrospectivos , Ultrassonografia Doppler/métodos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...